PT. Bopana Arga Prima Jaya

sql
Felix F-960 Quickly And Accurately Measures Ethylene Co2 And O2 Gas Analyzers
Hover to Zoom

Last Updated
13 Jan 2020
Country Origin
Indonesia
Minimum Order
1 Unit

Specification of

Felix F-960 Quickly and Accurately Measures Ethylene CO2 and O2 Gas Analyzers
Felix F-960 Ripen It! Gas Analyzer
The F-960 Ripen It! Gas Analyzer quickly and accurately measures ethylene, CO2, and O2 to assist with decision making throughout the produce ripening process. All three sensors work together to give you a clear picture of gas concentrations in ripening rooms. 

The Ripen It! is a handheld unit that can easily be transported into ripening rooms or connected to rooms through external ports. Data is conveniently transferred from the device to a network using Bluetooth or the removable 
SD card.

FEATURES

Measures C2H4, CO2 and O2
Displays results in under 30 seconds
Past records stored on the device
Handheld and lightweight
Internal data logging and storage (4GB SD card)
Battery lasts for 8+ hours
Display easily viewed in dimly lit environments



SPECIFICATIONS

Sampling Flow Rate: 70mL/min

Total Sampling Time: 90 seconds

Data Saving: Automated, 1 second intervals

Display: Sunlight visible transflective LCD

Operating Environment: 0° C - 50° C (0-90 % humidity non-condensing)

Operating Atmospheric Pressure: 500-1200mbar

Dimensions: 18 cm x 13.5 cm x 5.5 cm

Weight: 0.95 kg

Enclosure: Powder coated aluminum

Battery Life: 8.5 hours

Power Source: Removable rechargeable lithium-ion battery

PC Interface: USB and WI-FI SD card + Bluetooth

Data Recorded with Each Measurement: Ethylene, CO2 and O2 concentrations, date, time, RH, GPS location



Trigger Mode Measurements

  C2H4 CO2 O2

Sensor Type: Electrochemical Infrared Sensor, Pyroelectric detector Electrochemical

Range: 0-1000 ppm 0-100% 0-100%

Resolution: 1 ppm 0.01% 0.10%

Lower Detection Limit: 10 ppm 0.50% 0.30%

Sampling Volume: 35 ml 12 ml 12 ml

Response Time: 35 seconds 12 seconds 12 seconds

Accuracy (absolute): 10 ppm 0.50% 0.30%

Accuracy (relative): 5% 2% 3%

Offset Calibration: Weekly Weekly Weekly

Span Calibration: 3 months 12 months 6 months

Sensor Replaceable (by user): yes no yes

Lifetime: 1 year 5 years 2 years



Continuous Mode Measurements

  C2H4 CO2 O2

Sensor Type: Electrochemical Infrared Sensor, Pyroelectric detector Electrochemical

Range: 0-1000 ppm 0-100% 0-100%

Resolution: 1 ppm 0.01% 0.10%

Lower Detection Limit: 2 ppm 0.01% 0.10%

Response Time: 90 seconds 6 seconds 12 seconds

Accuracy (absolute): 2 ppm 0.01% 0.10%

Accuracy (relative): 5% 3% 2%

Offset Calibration: Weekly Weekly Weekly

Span Calibration: 3 months 12 months 6 months

Sensor Replaceable (by user): yes no yes

Lifetime: 1 year 5 years 2 years

We are the most complete distributor of laboratory equipment in Bogor. The products we sell have good quality and competitive prices.

Untuk keterangan lebih lanjut, silahkan download PDF ini :

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot