Simple to operate and weighing less than a kilogram, the F-950 uses an electrochemical cell to measure ethylene between 0-200 ppm. 
The F-950 is ideal for measuring ethylene production across a wide range of fruit types.

FEATURES
Measures C2H4, CO2 and O2
Displays results in under 30 seconds
Past records stored on the device
Handheld and lightweight
Internal data logging and storage (4GB SD card)
Battery lasts for 8+ hours
Display easily viewed in dimly lit environments
PolarCept!TM water filter for removing non-ethylene hydrocarbons


SPECIFICATIONS

Sampling Flow Rate: 70mL/min

Total Sampling Time: 80 seconds

Data Saving: Automated, 1 second intervals

Display: Sunlight visible transflective LCD

Operating Environment: 0° C - 50° C (0-90 % humidity non-condensing)

Operating Atmospheric Pressure: 500-1200mbar

Dimensions: 18 cm x 13.5 cm x 5.5 cm

Weight: 0.95 kg

Enclosure: Powder coated aluminum

Battery Life: 8.5 hours

Power Source: Removable rechargeable lithium-ion battery

PC Interface: USB and WI-FI SD card + Bluetooth

Data Recorded with Each Measurement: Ethylene, CO2 and O2 concentrations, date, time, RH, GPS location



Trigger Mode Measurements

  C2H4 CO2 O2

Sensor Type: Electrochemical Infrared Sensor, Pyroelectric detector Electrochemical

Range: 0-200ppm 0-100% 0-100%

Resolution: 0.1ppm 0.01% 0.10%

Lower Detection Limit: 0.15ppm 0.50% 0.30%

Sampling Volume: 35 ml 12 ml 12 ml

Response Time: 35 seconds 12 seconds 12 seconds

Accuracy (absolute): 0.15 ppm 0.50% 0.30%

Accuracy (relative): 5% 3% 2%

Offset Calibration: Weekly Weekly Weekly

Span Calibration: 3 months 12 months 6 months

Sensor Replaceable (by user): yes no yes

Lifetime: 1 year 5 years 2 years



Continuous Mode Measurements

  C2H4 CO2 O2

Sensor Type: Electrochemical Infrared Sensor, Pyroelectric detector Electrochemical

Range: 0-200 ppm 0-100% 0-100%

Resolution: 0.1 ppm 0.01% 0.10%

Lower Detection Limit: 0.2 ppm 0.01% 0.10%

Response Time: 80 seconds 6 seconds 12 seconds

Accuracy (absolute): 0.2 ppm 0.01% 0.10%

Accuracy (relative): 5% 3% 2%

Offset Calibration: Weekly Weekly Weekly

Span Calibration: 3 months 12 months 6 months

Sensor Replaceable (by user): yes no yes

Lifetime: 1 year 5 years 2 years

Ulasan

/5
Ulasan
5
4
3
2
1

Foto dari Pembeli

Ulasan dari Pembeli

Filter
Semua
Dengan Foto
5
4
3
2
1
Telepon
Request a Quote
Produk Siap di Pesan
Rp 0
1
Bendera Indonesia Indonesia  |  Bendera Inggris English
Ingin menghubungi kami?
Klik tombol dibawah
Logo IDT
Chatbot